Expansion Tank Sizing Calculator

Size a closed-loop expansion tank from system volume, fluid type, temperature, system pressure, tank precharge and fill pressure. Results in gallons and litres.

System
Pressure (psi)
Result
gallons
litres
Notes

About Expansion Tank Sizing Calculator

Water expands between cold fill and hot running, and a sealed loop has no way to release that volume - so the tank absorbs it. Size it against the system volume, the temperature swing and the pressure window allowed by the relief valve.

Expansion Tank Sizing Calculator gives the tank volume in gallons and litres for closed hydronic loops.

Features

  • Fluid factors: Water, 30% or 50% glycol.
  • Total volume: System volume feeds the math.
  • Pressure window: Precharge, fill and relief.
  • Accept volume: Real tank capacity used.
  • Live update: Results while you type.
  • Export: Text, CSV or JSON report.

How to Use

  1. Enter total system volume (pipes, radiators, boiler).
  2. Pick fluid and the high temperature.
  3. Set precharge, fill pressure and relief.
  4. Read tank size in gallons and litres.
  5. Export the result if needed.

Examples

Example 1. A 50-gallon loop of water heating to 190 F running at 12 psi with a 30 psi relief and a 12 psi precharge needs roughly a 3-gallon tank.

Example 2. Glycol at 50% expands faster - the same 50-gallon loop wants closer to a 4-gallon tank, which is why manufacturers ask for the fluid type.

Benefits

  • Closed-loop correct: Standard accept-volume method.
  • Glycol aware: 30% / 50% mix factors.
  • Dual units: Gallons and litres.
  • Free and private: No uploads, no logging.

Frequently Asked Questions

What does the expansion tank do?
Water expands as it heats and has nowhere to go in a sealed loop - the pressure would climb until a relief valve blows. The expansion tank holds that extra volume, so pressure stays under control.
Water or glycol?
Glycol expands more than water at the same temperature and carries more heat. The calculator uses a separate fluid expansion factor for water and a 30% or 50% glycol mix.
What are precharge and fill pressures?
The precharge is the air pressure set in the tank before the system is filled. The fill (or cold) pressure is the operating pressure when the loop is full and cold. The difference sets how much volume the tank accepts before the relief valve opens.
How does accept volume work?
The tank’s usable space is the volume between the precharge and the relief setting. At the precharge the diaphragm covers everything; heat raises pressure into the tank’s air cushion - that cushion is the accept volume.
Is this accurate for closed loops?
Yes - it follows the standard closed-loop method: fluid expansion volume divided by the acceptance fraction, which comes from the absolute pressure swing between precharge and relief.
Is my data stored?
No. Everything runs in your browser; nothing is uploaded, saved or logged.