Fuse Size Calculator

Suggest a standard fuse rating from the load current, continuous-load portion and load type (gG or aM). A planning aid that shows the required conductor ampacity.

Circuit load
Enter the working current. Motors are protected by aM fuses near 120% FLA; general loads by gG fuses sized on the design current.
Suggested Fuse
fuse (A)
min wire amps
Notes

About Fuse Size Calculator

Fuses are the quiet guardians of the panel: no lever, no label reader, just a calibrated element that parts company with the circuit the moment it is asked for too much.

Fuse Size Calculator suggests a standard fuse rating from the circuit current, the continuous portion and the load type - picking gG or aM guidance and showing the minimum conductor ampacity alongside.

It is a planning aid. Final selection must follow the code and the fuse manufacturer data in force.

Features

  • Load in amps: Enter the measured or computed current.
  • Continuous load: 125% applied to continuous parts.
  • gG or aM: Load-type guidance for the fuse class.
  • Standard ratings: Next IEC/NEC fuse size chosen for you.
  • Conductor check: Minimum ampacity for the cable.
  • Single or 3-phase: Formula aware of the system.
  • Export: Copy or download as text, CSV or JSON.

How to Use

  1. Enter the load current in amps.
  2. Enter the continuous portion of that load.
  3. Choose the load type (general, motor, transformer).
  4. Select the standard in force.
  5. Read the suggested fuse size and minimum cable ampacity.
  6. Export the sizing note if needed.

Examples

Example 1 — Heater circuit. 23 A continuous at 230 V: design 28.75 A, an 32 A gG fuse, cable at least 29 A.

Example 2 — Motor. 20.8 A FLA: an aM fuse close to 25 A, or a gG at 32 A to ride the start.

Example 3 — Mixed. 10 A continuous plus 6 A non-continuous: 18.5 A design, a 20 A fuse.

Example 4 — 3-phase. 24.1 A running at 400 V: 25 A aM or 32 A gG with a matching cable.

Benefits

  • Design current right: Continuous 125% applied automatically.
  • Rating picked: Next standard fuse size chosen.
  • Class guidance: gG versus aM matched to the load.
  • Wire matched: Minimum conductor ampacity shown.
  • Free and private: No uploads, no accounts, no logging.

Frequently Asked Questions

How do I size a fuse?
Start from the circuit current, count the continuous portion at 125%, then choose the next standard fuse rating at or above that design current. The fuse must pass the load while protecting the cable.
What is the difference between gG and aM fuses?
gG (general purpose) protects cables and general loads and clears low overcurrents. aM (motor) withstands motor starting currents and is matched to a motor protective device; it is designed for protection against short-circuit current.
What standard fuse ratings exist?
IEC gG ratings step through 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 200, 250, 315, 400 A and up. The calculator picks the next rating at or above the required value.
Why is a fuse sized above the running current?
A fuse must carry the working current without aging the element or nuisance-blowing, yet open before the cable is damaged. The headroom covers inrush and tolerances on the load.
How do I match the fuse to the cable?
The fuse rating should not exceed the conductor ampacity (with derating applied). The calculator shows the minimum cable ampacity so you can pick the conductor to match.
Do I use NEC or IEC rules?
Both conventions apply the same physics but differ in tables and fuse availability. Select the standard in force; the result is a suggestion to confirm against the code.
Is my data stored?
No. Everything runs in your browser; nothing is uploaded, saved or logged.